| Model / Part |
LR523F (Master Indicator for EML-500) |
| Operating Temperature |
–15 °C to +55 °C (operating) |
| Storage / Non-operating Temperature |
–20 °C to +60 °C |
| Humidity |
Up to 95% RH (non-condensing) |
| Vibration Tolerance |
5–12.5 Hz: ±1.6 mm; 12.5–25 Hz: ±0.38 mm; 25–50 Hz: ±0.1 mm |
| Power / Supply Voltage |
The EML500 system (Master Unit) supports 100–115 VAC or 200–230 VAC, ±10%, 50/60 Hz |
| Power Consumption |
~ 80 VA (for full system) |
| Input / Interfaces |
• Analog signal (current): 0 → 20 mA or 4 → 20 mA (for external systems)
• Pulse output: photocoupler/contact (200 pulses per nautical mile)
• Serial/digital output: NMEA 0183 format; internal digital link between master unit & indicator
• Analog voltage output: 0 V → 5 V DC or 1 V → 5 V DC (optional) |
| Withstanding / Insulation |
• Withstanding voltage: 1500 V AC for 1 min (excluding electronics)
• Insulation resistance: ≥ 10 MΩ @ 500 V megger (excluding electronics) |
| Display / Readouts |
LED digital display showing: speed (knots), total distance (nm), trip distance, longitudinal & transverse speeds, resultant speed & direction (dual axis), GPS mode, error codes |
| Alarms / Diagnostics |
Self-diagnostic error detection; alarm relay contacts (NC/NO) configurable via DIP switches in master unit |
| Memory / Backup |
Backup battery (in master unit) stores parameters; data lost if battery is replaced |
| Mechanical / Mounting |
Flush-mount (LR523-D) or desk/wall mount (LR523-W) variants available |
| System Modes & Operation |
• Display cycling: speed & distance → trip → transverse/resultant → back
• LOG/GPS selection (speed source)
• Test mode, alarm setup, zero/span calibration, sensitivity adjustment
• Supports single-axis & dual-axis sensors
• Compatible with sensor diameters Φ35 mm, Φ48 mm, Φ70 mm (single or double bottom installation) |
There are no reviews yet.