The CSC-656 Relay Filter Board acts as a protective and routing interface between the ship’s main power supply and the scanner’s internal motors and electronics.
-
Primary Function: It filters incoming electrical noise to prevent interference with radar signal processing. It also utilizes relays to control the high-current distribution required for the Scanner Motor (rotation) and the Heater circuits.
-
System Integration: It is typically located in the Scanner Unit (e.g., NKE-1125 or NKE-1130). It works in tandem with the CBD-1682A power board you previously inquired about.
-
Durability: As an “Up-mast” component, it is designed with heavy-duty relays to withstand the vibration and temperature fluctuations of the mast environment.