Furuno, BR-540 Cabin Panel(BNWAS)

$150.00Earn 150 points!

2 in stock

DUTY LED
The DUTY LED is illuminated (in green) when the BNWAS is active and according to
type of Cabin Panel:
Cabin Panel set as Captain, Backup Officer or Public is illuminated in all phases of
the watch alarm.

Note: The LED is disabled when a 4-core cable (MPYC-4 or equivalent) connects
Cabin Panel(s) to the Processor Unit.

ALARM LED
The ALARM LED lights (in red) and the buzzer sounds in response to an alarm sent
to the 2nd and 3rd stages.

TEST switch
The TEST switch checks the LEDs and the buzzer for correct operation. The connection between the Cabin Panel and Processor Unit is also checked. (This check is not available when those units are connected to each other with a 4-core cable.)

Technical Specification

You can check the connection between the Processor Unit/Cabin Panel/Timer Reset
Panel. The tested panel sends a test signal to the Processor Unit. The Processor Unit
receives the test signal then commands that panel to light or flash its LEDs and sound
its buzzer.
Note: If the 4-core cable (MPYC-4, or equivalent) connects Cabin Panel(s), use the
EMG call on the Main Alarm Panel to do the check. The TEST switch on the Cabin
Panel is disabled when the 4-core cable is used.

Push the TEST switch or RESET button (long-push) to start the test. The tested panel
is normal if its LEDs and buzzer perform.